ADMA
Contact us

Dräger PointGard 3100

Toxic Gases and Oxygen Detectors
Dräger PointGard 3100

Complete 1-channel gas detection system

  • Complete 1-channel gas detection system
  • Monitors toxic gases or oxygen in ambient air
  • Features a high-performance plug-and-play electrochemical DrägerSensor
  • Robust, compact housing with IP66 protection

Discover PointGard: Your all-in-one solution for gas detection

Highlights

The Dräger PointGard 3100 is a complete 1-channel gas detection system for measuring toxic gases or oxygen in ambient air. In its robust yet compact housing with IP66 protection class, you have all the necessary alarm equipment needed.

All-in-One

The PointGard 3100 is the optimal solution for all those who need a gas detection system but who do not want to go through the hassle of assembling all the necessary components. It contains the measuring function of a transmitter, the assessment function of a controller and the necessary alarm equipment, such as flashing lights and horn. The AC versions of the PointGard 3100 can be operated with an optional power plug at any standard power socket. If the measuring location is not suitable for mounting the PointGard, you can remove the integrated sensor and place it up to 30 m away using the corresponding remote accessories. In addition, appropriate accessories are also available for use in pipes and ventilation shafts.

The Application

Use the PointGard 3700 where gas concentrations need to be monitored locally. A typical application is the measurement of hazardous gases in unventilated or closed rooms. For this, the PointGard 3100 is installed outside the room at the entrance and the sensor in the room where the substance is monitored. This way, you are informed about the gas concentration before entering the room. If the alarm limits are exceeded, the PointGard warns you with its integrated alarm devices. It can also trigger automatic ventilation so that the concentration is lowered and the room can be entered again without danger. In case of oxygen monitoring, ventilation would continue until a sufficiently high concentration is present again.

The Measurement Technology

Inside the PointGard 3100, you will find the proven electronics of our Dräger Polytron 8100. Our electrochemical DrägerSensors are used for the measurement. They are characterised by a long service life and long-term stability. With the various sensors that can be used in the PointGard 3100, more than 100 toxic gases can be measured. The DrägerSensors allow continuous measurement even under the most difficult conditions. Most DrägerSensors support a wide temperature range from -40 °C to +65 °C.

The Integrated Alarm Equipment

The PointGard 3100 includes visual and audible alarms. The bright and long-lasting flashing lights warn of danger from a distance in orange (pre-alarm) and red (main alarm). If a distinction is made between safe and unsafe conditions, there are combinations in green (safe) and red (unsafe) or green (safe) and blue (unsafe). The integrated horn has a sound pressure of 85-100 dB. It was selected for industrial use in noisy environments. You can reduce the volume for less noisy environments, for example in the laboratory.

The Power Supply

The PointGard 3100 contains a 120 … 230 VAC/ 24 VDC power supply. You can also order it with a power cable and country-specific plug as an option. If a local 24 VDC supply is already available, a variant without power supply unit is also available.

The Operability

The measured value, gas name and measuring unit are permanently shown on the display. If required, the concentration history of the last 15 minutes can also be shown. The display has a backlight in red or green to ensure readability even in poor lighting conditions. The colours can be set via a slide switch inside the device. Below the display are three status LEDs in green (operational), yellow (error) and red (alarm). All settings on the PointGard 3100 are made via a password-protected menu. The three-button control allows quick navigation through the menu items. Measuring range and alarm thresholds are already set to the usual values after plugging the sensor. They can be adjusted at any time.

The Interfaces

In addition to the integrated alarm means, the PointGard 3100 also has potential-free changeover relays. This enables additional automated switching measures. Relays are available for A1, A2 and faults. Moreover, an external switching contact, for example a fault contact of neighbouring machines, can be read in and thus the green light (safe status) on the PointGard 3100 can be switched off. For integration into higher-level systems (visualisation systems, data acquisition systems, PLCs, central gas warning systems), the analog 4-20 mA current interface according to NE 43 can be used. HART® communication allows you to synchronise settings with a connected Dräger REGARD 3000 or Dräger REGARD 7000. Furthermore, remote access is possible via HART® using Dräger PolySoft software or other HART® HHT.

Similar Products

Dräger PIR 7200

Explosion proof point infrared gas detector

Dräger PointGard 3720

Complete 1-channel gas detection system

Dräger Polytron 3000

Monitors over 60 toxic gases and oxygen in ambient air

Dräger Polytron 5100 EC

Monitors toxic gases or oxygen in standard applications

Dräger Polytron 5720 IR

Monitors carbon dioxide in volume percentage or ppm

Dräger Polytron 6100 EC WL

Wireless transmitter for continuous monitoring of toxic gases and oxygen

Dräger Polytron 8100 EC

Top-of-the-line explosion-proof transmitter

Dräger Polytron® 7000

Monitors toxic gases or oxygen

Dräger Polytron® 8720 IR

Advanced explosion-proof transmitter for carbon dioxide detection

Dräger VarioGard 2320 IR

Monitors possible gas leaks or workplace exposure limits of carbon dioxide

Dräger VarioGard 3000 EC Transmitter

Detects toxic gases such as CO, NO2, NO, NH3, and oxygen

Dräger VarioGard 3320 IR

Detects carbon dioxide in the ambient air

Dräger X-node

Wireless IoT solution for process monitoring and analysis

Refrigerant Transmitter

Detects refrigerant gas leaks using infrared technology

SafEye™ Quasar 950/960

Open-path UV gas detection system
1/15